{"id":6208,"date":"2024-08-15T11:51:11","date_gmt":"2024-08-15T04:51:11","guid":{"rendered":"https:\/\/yasudaseiki.vn\/?post_type=product&#038;p=6208"},"modified":"2024-08-15T11:51:11","modified_gmt":"2024-08-15T04:51:11","slug":"no-258-%e3%82%a4%e3%83%b3%e3%83%91%e3%82%af%e3%83%88%e3%83%86%e3%82%b9%e3%82%bf%e3%83%bc","status":"publish","type":"product","link":"https:\/\/yasudaseiki.vn\/zh-hans\/product\/no-258-%e3%82%a4%e3%83%b3%e3%83%91%e3%82%af%e3%83%88%e3%83%86%e3%82%b9%e3%82%bf%e3%83%bc\/","title":{"rendered":"No.258 \u30a4\u30f3\u30d1\u30af\u30c8\u30c6\u30b9\u30bf\u30fc"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td colspan=\"3\"><strong>Specification may change without notice.<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Main Body Dimensions<\/strong><\/td>\n<td colspan=\"2\">W500 \u00d7 D350 \u00d7 H850 mm<br \/>\n(Digital Touch Panel Spec : D+250mm, Curtain for Littler Control : W+520mm,<br \/>\nSafety Cover : W + 500mm \u00d7 H + 275mm)<\/td>\n<\/tr>\n<tr>\n<td><strong>Main Body Weight<\/strong><\/td>\n<td colspan=\"2\">125 kg<br \/>\n(Digital Ver. : + 5kg, Curtain for Littler Control: + 5, Safety Cover: + 75 kg)<\/td>\n<\/tr>\n<tr>\n<td><strong>Power Source<\/strong><\/td>\n<td colspan=\"2\">Digital Type without Safety Cover\u3001\u00a0AC 100 V, 1-Phase, 3 A, 50\/60 Hz<br \/>\nDigital Type with Safety Cover \u3001AC 100 V, 1-Phase, 5 A, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Accessories<\/strong><\/td>\n<td colspan=\"2\">Assortment of Tools<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203b\u00a0It is listed in the below orders.<br \/>\n\u30fb258 JIS\/ISO<br \/>\n\u30fb258 ASTM<\/p>\n<div class=\"su-spoiler su-spoiler-style-fancy su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\">JIS\/ISO\uff08\u2190open)<\/div>\n<div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<table>\n<thead>\n<tr>\n<th>Standard<\/th>\n<td colspan=\"3\"><strong>JIS\/ISO<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Test Method<\/th>\n<td colspan=\"2\">Charpy Impact Test<\/td>\n<td>Izod Impact Test<\/td>\n<\/tr>\n<tr>\n<th>Base Standards<\/th>\n<td colspan=\"3\">JIS B7739:2011\u3001ISO 13802:1999<\/td>\n<\/tr>\n<tr>\n<th>Reference Standards<\/th>\n<td colspan=\"2\">JIS K7111-1:2012\u3001ISO 179-1:2010<\/td>\n<td>JIS K71110:1999\u3001ISO 180:2000<\/td>\n<\/tr>\n<tr>\n<th>Hammer Capacity<br \/>\n\u203b1(J)<\/th>\n<td>0.5, 1, 2, 4, 5<\/td>\n<td>7.5, 15, 25\u203b2<\/td>\n<td>1, 2.75, 5.5, 11, 22<\/td>\n<\/tr>\n<tr>\n<th>\u3000Anvil<\/th>\n<td colspan=\"2\">JIS\/ISO Charpy Anvil<\/td>\n<td>JIS\/ISO\/ASTM Izod Anvil<\/td>\n<\/tr>\n<tr>\n<th>JIS\/ISO Charpy Anvil Lift<\/th>\n<td>Necessary<\/td>\n<td>\u30fc<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Hammer Impact Point Setting Gauge<\/th>\n<td colspan=\"3\">JIS\/ISO Hammer Impact Point Setting Gauge<\/td>\n<\/tr>\n<tr>\n<th>Specimen Setting Gauge<\/th>\n<td colspan=\"2\">JIS\/ISO Charpy Specimen Setting Gauge<\/td>\n<td>JIS\/ISO \u00a0Izod Specimen Setting Gauge<\/td>\n<\/tr>\n<tr>\n<th><strong>Option<\/strong><\/th>\n<td colspan=\"3\">Digital(Touch Panel, PC)Ver., Safety Cover(Full Cover),Curtain for Littler Control, Hammer Additional Weight,<br \/>\nMini Printer (Thermal paper 10 rolls)\u203b3, CSV Down load Tool(includes LAN cable)\u203b4, Analog Scale &amp; Pointer, Windows PC \u203b5, Additional Weight for Main Body \u203b6<\/td>\n<\/tr>\n<tr>\n<th>Impact speed<\/th>\n<td>2.9m\/s<\/td>\n<td>3.8m\/s<\/td>\n<td>3.5m\/s<\/td>\n<\/tr>\n<tr>\n<th>Lift-up Angle<\/th>\n<td colspan=\"3\">150\u00b0<\/td>\n<\/tr>\n<tr>\n<th>Hammer Edge<\/th>\n<td colspan=\"2\">R2\u00b10.5mm\u3001Angle\uff1a30\u00b11\u00b0<\/td>\n<td>R0.8\u00b10.2mm<\/td>\n<\/tr>\n<tr>\n<th>Anvil Edge Radius<\/th>\n<td>R1\u00b10.1mm<\/td>\n<td>\u30fc<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Anvil Supporting Edge<\/th>\n<td colspan=\"2\">\u30fc<\/td>\n<td>R0.2\u00b10.1mm<\/td>\n<\/tr>\n<tr>\n<th>Anvil Supporting Length<\/th>\n<td colspan=\"2\">62+0.05mm\u203b7<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Anvil-Edge Distance<\/th>\n<td colspan=\"2\">\u30fc<\/td>\n<td>R22\u00b10.2mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\u203b1 Custom Hammers can also be provided. kgf\/cm Hammers are also available.<br \/>\nkinds of additional weights can be attached to a single hammer.<br \/>\n\u203b2 50J Hammer is not available.<br \/>\n\u203b3 Setting Gauge differs depending on the size of specimen thickness.<br \/>\n\u203b4 Available when Digital Touch Panel Spec. is chosen.<br \/>\n\u203b5 Required for the CSV Download Tool for the Digital Touch Panel Type spec.,<br \/>\nand Digital PC Type spec.<br \/>\n\u203b6 Required when more than 15 J Hammer is used.<br \/>\n\u203b7 This length is for JIS K7111-1. If other lengths are required, please let us know.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div class=\"su-spoiler su-spoiler-style-fancy su-spoiler-icon-plus\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\">ASTM\uff08\u2190open)<\/div>\n<div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\n<div><\/div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Standard<\/th>\n<td colspan=\"3\"><strong>ASTM<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>Test Method<\/th>\n<td colspan=\"2\">Charpy Impact Test<\/td>\n<td>Izod Impact Test<\/td>\n<\/tr>\n<tr>\n<th>Base Standards<\/th>\n<td colspan=\"3\">\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Reference Standards<\/th>\n<td colspan=\"2\">ASTM D6110-10<\/td>\n<td>ASTM D256-10<\/td>\n<\/tr>\n<tr>\n<th>Hammer Capacity<br \/>\n\u203b1(J)<\/th>\n<td colspan=\"2\">2.7 or More<br \/>\n(Track Record: 0.5,1,2,4,5,7.5,15,25)<\/td>\n<td>2.7<br \/>\n(Track Record: 1,2.75,5,11,22)<\/td>\n<\/tr>\n<tr>\n<th>\u3000Anvil<\/th>\n<td colspan=\"2\">ASTM Charpy Anvil<\/td>\n<td>JIS\/ISO\/ASTM Izod Anvil<\/td>\n<\/tr>\n<tr>\n<th>JIS\/ISO Charpy Anvil Lift<\/th>\n<td colspan=\"2\">\u30fc<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Hammer Impact Point Setting Gauge<\/th>\n<td colspan=\"3\">ASTM Hammer Impact Point Setting Gauge<\/td>\n<\/tr>\n<tr>\n<th>Specimen Setting Gauge<\/th>\n<td colspan=\"2\">ASTM Charpy Specimen Setting Gauge<\/td>\n<td>ASTM \u00a0Izod Specimen Setting Gauge<\/td>\n<\/tr>\n<tr>\n<th><strong>Option<\/strong><\/th>\n<td colspan=\"3\">Digital(Touch Panel, PC)Ver., Safety Cover(Full Cover),Curtain for Littler Control, Hammer Additional Weight,<br \/>\nMini Printer (Thermal paper 10 rolls)\u203b3, CSV Down load Tool(includes LAN cable)\u203b4, Analog Scale &amp; Pointer, Windows PC \u203b5, Additional Weight for Main Body \u203b6<\/td>\n<\/tr>\n<tr>\n<th>Impact speed<\/th>\n<td colspan=\"2\">3.46m\/s<\/td>\n<td>3.5m\/s<\/td>\n<\/tr>\n<tr>\n<th>Lift-up Angle<\/th>\n<td colspan=\"3\">150\u00b0<\/td>\n<\/tr>\n<tr>\n<th>Hammer Edge<\/th>\n<td colspan=\"2\">R3.17\u00b10.12mm\u3001Angle\uff1a45\u00b12\u00b0<\/td>\n<td>R0.8\u00b10.2mm<\/td>\n<\/tr>\n<tr>\n<th>Anvil Edge Radius<\/th>\n<td colspan=\"2\">R3.17\u00b10.12mm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th>Anvil Supporting Edge<\/th>\n<td colspan=\"2\">\u30fc<\/td>\n<td>R0.25\u00b10.12mm<\/td>\n<\/tr>\n<tr>\n<th>Anvil Supporting Length<\/th>\n<td colspan=\"2\">101.6\u00b10.5mm<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<tr>\n<th>Anvil-Edge Distance<\/th>\n<td colspan=\"2\">\u30fc<\/td>\n<td>R22\u00b10.05mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div><\/div>\n<p>\u203b1 Custom Hammers can also be provided. kgf\/cm Hammers are also available.<br \/>\nkinds of additional weights can be attached to a single hammer.<br \/>\n\u203b2 50J Hammer is not available.<br \/>\n\u203b3 Setting Gauge differs depending on the size of specimen thickness.<br \/>\n\u203b4 Available when Digital Touch Panel Spec. is chosen.<br \/>\n\u203b5 Required for the CSV Download Tool for the Digital Touch Panel Type spec.,<br \/>\nand Digital PC Type spec.<br \/>\n\u203b6 Required when more than 15 J Hammer is used.<br \/>\n\u203b7 This length is for JIS K7111-1. If other lengths are required, please let us know.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>JIS K7110\u3001K7111-1\u3001ASTM D256\u3001D6110\u3001ISO 179-1:2010\u3001180<\/p>\n<ul>\n<li>This pendulum type impact tester for plastic enables the operator to conduct both Charpy and Izod impact test just by changing the hammer and the anvil.<\/li>\n<li>The tester can be attached with an optical rotary encoder, so that the impact data can be saved in a computer.<\/li>\n<\/ul>\n<p>\u2191\u3000DIGITAL\/TP\u3000TYPE<\/p>\n","protected":false},"featured_media":4161,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[92],"product_tag":[],"class_list":{"0":"post-6208","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-product","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/product\/6208","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/comments?post=6208"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/media\/4161"}],"wp:attachment":[{"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/media?parent=6208"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/product_cat?post=6208"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yasudaseiki.vn\/zh-hans\/wp-json\/wp\/v2\/product_tag?post=6208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}